Dual 1Gb iSCSI-to-SATA 3Gb/s RAID 6 Storage System IP-SAN Simplicity, Proven RAID Architecture

Our Price: Call for Pricing!
Click here to jump to more pricing!
Overview:
PROMISE VTrak M-Class iSCSI products leverages a technology that provides wide interoperability with rich iSCSI features including immediate data, CHAP, VLAN, Link Aggregation, Jumbo Frame, iSNS for network device discovery and near wire speed performance. These functions give network administrators the flexibility to solve tough storage problems with minimum disruption to clients.
The PROMISE VTrak parallel SCSI product line is optimized for organizations deploying small to medium application servers, disk-to-disk backup and direct-attach storage solutions. Dual Ultra 320 SCSI host interface channels offer the ease of management and performance required by companies running popular departmental and back-office applications. The VTrak parallel SCSI product line combines advanced connectivity and storage features – sophisticated functionality, exceptional performance, rock-solid reliability, and high availability – with intelligent system design for a very affordable solution.
Highlights
- 12 hot-swappable SATA drive bays in a robust 2U chassis
- RAID 0, 1, 1E, 5, 6, 10,and 50 support.
- 256MB ECC shared cache (up to 1GB), with 72-hour battery backup included.
- iSCSI CHAP, ERL 0, immediate data, iSNS client, VLAN, Link Aggregation (Trunking) and Jumbo Frames with up to 64 concurrent sessions.
- Hardware based TCP/IP and iSCSI Offload engine
- Supports iSCSI Boot from SAN
- Comprehensive embedded web-based management via Ethernet – WebPAM PROe
- PerfectRAID and Predictive Data Migration technology for robust error handling and recovery.
- LCD Panel support (optional)
- Intelligent enclosure management, including thermal, voltage, and fan speed monitor and adjustment automation.
Features:
IP-SAN flexibility and value
Promise VTrak M-Class iSCSI products are a new generation of our technology that provides wide interoperability with rich iSCSI features including immediate data, CHAP, VLAN, Link Aggregation, Jumbo Frame, iSNS for network device discovery and near wire speed performance. These functions give network administrators the flexibility to solve tough storage problems with minimum disruption to clients. The VTrak M610i/M310i/M210i builds on Promise's success of rock-solid iSCSI technology at an affordable price.
High storage density
VTrak M-Class Products support up to 16/12/8 off-the-shelf 3.5" SATA 3Gb/s or 1.5Gb/s drives per system in a standard 3U/2U 19" rack space. By taking advantage of unsurpassed capacity of SATA drives, the VTrak system delivers the highest capacity levels available. Deliver massive storage to capacity-hungry applications such as disk-to-disk backup, media serving, video surveillance and compliance storage.
RAID 6 reliability
RAID 6 (double-parity) delivers the highest level of reliability and data protection in a cost-effective solution. As the capacity of storage arrays increases, so does the risk of encountering unrecoverable errors. RAID 6 has two sets of parity from which the array can be rebuilt; it also remains available through up to two drive failures. This improves overall data protection, without adversely affecting performance and dramatically reduces the risk of catastrophic data loss during RAID rebuilds.
Easy to install and manage
The entire VTrak line features embedded management software, WebPAM PROe, which eliminates the need to install additional software on the network. All VTrak systems in your network can be configured and monitored through a single, easy-to-manage web-based graphic user interface. The software works through the VTrak system's Ethernet port – locally, across a LAN, or across an internet connection – to configure and monitor one or multiple VTrak system(s) and provide error reporting through pop-up messages, event logging, or email notification. The VTrak family also simplifies integration with third-party management applications using industry-standard SNMP protocols.
Specifications:
VTrak M210i | VTrak M310i | VTrak M610i | |
---|---|---|---|
System and Controller Features | |||
Drive Support | 8 Drives (3.5" x 1" only) | 12 Drives (3.5" x 1" only) | 16 Drives (3.5" x 1" only) |
Supports 3Gb/s and 1.5Gb/s SATA drives; Supports Native Command Queuing (NCQ) and Tagged Command Queuing (TCQ); Staggered physical drive spin-up; Supports 48-bit LBA SATA drives | |||
External I/O Ports | Dual full-duplex 1Gb iSCSI ports over copper cabling | ||
Data Cache | Shared 256MB predictive data cache (max. to 1GB/Optional); Automatic write cache destaging; 72-hour battery backup included (2 cell battery for 256/512MB, 4 cell battery for 1GB) | ||
iSCSI Features | Full hardware-based TCP/IP offload (TOE) Full hardware-based iSCSI Offload w/ header/data digest Immediate Data, Error Recovery Level 0 Up to 64 concurrent sessions CHAP (one-way or mutual) for authentication iSNS and DHCP for device discovery iSCSI VLAN 802.1 q, Link Aggregation(Trunking 802.3 ad) , Jumbo Frame 9k Microsoft iSCSI MPIO support |
||
Command Queue Depth of RAID Controller | 1024 commands | ||
Operational Features | |||
RAID Levels | RAID 0, 1, 1E, 5, 6, 10, 50 – Any combination of these RAID levels can exist at the same time ; Configurable RAID stripe size: 64K, 128K, 256K, 512K and 1MB stripe size per disk; Background task priority tuning: adjustment of minimum I/O reserved for server use during all background tasks | ||
Hot spares | Multiple global or designated dedicated hot-spare drives with revert options | ||
Max LUNs per subsystem | 256 in any combination of RAID levels and array types | ||
Max LUNs per array | 32 logical drives (LUNs); Supports LUN Carving by allowing an array to be divided into multiple logical drives; RAID level, stripe size, sector size and cache policy can be configured per LUN. | ||
LUN Masking and Mapping | Dynamically change LUN ID & initiator access control | ||
Disk Data Formats | Supports Disk Data Format (DDF) for drive roaming between VTrak systems. | ||
Background Activities | Media Patrol; Background synchronizing; Initialization; Rebuild; Redundancy Check; SMART condition pooling; OCE (Online Capacity Expansion); RLM (RAID Level Migration); Priority Control, Throttle Rate Control and watermarking per BGA (background activities) | ||
RAID Robustness | Physical Drive Error Recovery: PDM (Predictive Data Migration): Replace un-healthy disk member in array, and keep array on normal status during the data transition between healthy HD and replaced HD, Bad Sector Mapping, Media Patrol, SMART, Hard/Soft Reset, HD Power on/off control to recover HD from error status. Array Error Recovery: Data recovery from bad sector or failed HD for redundant RAID, RAID 5/6 inconsistent data Prevent (Write Hole Table), Data content Error Prevent (Read/Write Check Table); NVRAM event logging |
||
SCSI Commands | Supports extensive SCSI command set equivalent to SCSI/FC hard disk drives; Variable sector size (512Byte to 4kB) to break OS 2TB limitation; 16Byte CDB support for 64-bit LBA address | ||
System Management | |||
Supported Operating Systems | Windows Vista, Windows 2003, Windows XP, Windows 2000, Linux (Red Hat, SuSE), Netware | ||
Management Tools | Operating System independent; Localized in multiple languages; SSL Security support; WebPAM PROe via out-of-band Ethernet; Command Line Interface via RS-232 serial port or Ethernet (Telnet); Command Line Utility via RS-232 Serial Port or Ethernet (Telnet); Standard Management Protocols: SNMP; Auto, Express and Advanced configuration support for novice and skilled users | ||
Management Interfaces/Protocols | Ethernet, RS-232 Serial Port; SNMP,SSL, Telnet; Email, audible (buzzer), visible (LEDs) alarms, and LCD (optional) | ||
Mechanical Specifications | |||
Current (Maximum) | 8 A @ 100 Vac; 4 A @ 200 Vac (current rating with two power cords) | ||
Power Supply | Dual 300W, 100-240 Vac auto-ranging, 50-60 Hz, dual hot swap and redundant with PFC, N+1 design | Dual 300W, 100-240 Vac auto-ranging, 50-60 Hz, dual hot swap and redundant with PFC, N+1 design | Dual 400W, 100-240 Vac auto-ranging, 50-60 Hz, dual hot swap and redundant with PFC, N+1 design |
Power Consumption | 114.88Watts (under load w/o HDD), 347.72Watts (under load with SATA HDD) | 116.29Watts (under load w/o HDD), 426.74Watts (under load with SATA HDD) | |
Temperature/ Humidity | 5° ~ 40°C (-40° ~ 60°C storage temperature); Maximum relative humidity = 95% | ||
Dimensions (H x W x D) | 8.9 x 44.6 x 56.1 cm (3.5 x 17.6 x 22.1 in) | 8.9 x 44.6 x 56.1 cm (3.5 x 17.6 x 22.1 in) | 13.1 x 44.6 x 56.1 cm (5.2 x 17.6 x 22.1 in) |
Weight | 20.5 kg (45.2 lbs) without drives, 24.5 kg (54 lbs) with 8 drives* | 21 kg (46.26 lbs) without drives, 27.0 kg (59.47 lbs) with 12 drives* | 26.7 kg (58.7 lbs) without drives, 34.7 kg (76.3 lbs) with 16 drives* |
Safety | CE, FCC Class B, VCCI, BSMI, CB, MIC, C-Tick, UL, TUV | ||
Warranty and Support | 3 years complete system; 24x7 worldwide email and phone support with highly experienced technical support technicians (English only) |
Documentation:
Download the PROMISE VTrak M-Class iSCSI Datasheet (PDF).
Pricing Notes:
- Pricing and product availability subject to change without notice.